Posted by
hans2 on
Mar 12, 2016; 4:57pm
URL: https://itus.accessinnov.com/Bridge-mode-Internet-OK-but-no-Admin-access-tp371p413.html
ITUS folded mainly due to hardware manufacturing issues, see the PCM
article.
When you do powercycle, do you get back to 1.51SP or to RC2? Since i
replace all backup images with 1.51 and the ubiots then this powercycle
issue did not happen anymore
not sure why this is the case, something in the stage1/2 loaders
These are the files that I have in the boot sector
-rwxr-xr-x 1 root root 35862152 Nov 26 03:04 ItusbridgeImage
-rwxr-xr-x 1 root root 58078856 Nov 26 03:02 ItusgatewayImage
-rwxr-xr-x 1 root root 40859016 Nov 27 13:08 ItusrestoreImage
-rwxr-xr-x 1 root root 58144392 Nov 26 03:01 ItusrouterImage
-rwxr-xr-x 1 root root 470976 Mar 27 2015 octboot2.bin
-rwxr-xr-x 1 root root 1138416 May 27 2015 u-boot-octeon_rhino_itus7x.bin
note the date and size of octboot and u-boot
to get this you need to go to CLI:
1) cd /tmp
2) mkdir save
3) mount /dev/mmcblk0p1 /tmp/save
4) cd /tmp/save
5) ls -al
6) umount /tmp/save
step 3 mounts the boot sector, this is normally also done by the upgrade script.
check at step 5 the file dates and sizes.
TODO - i will update the upgrade script to also update the stage 1/2 boot loaders.
No more: Shield Pro v1, Chaos Calmer, FW 1.51 SP1